Reliability: Engineered for high reliability in critical environments
Customs Tariff Number: 85363010
High-Level Current Input: Supports standard 4–20 mA signals from industrial transmitters
System Control: Enables operations such as start
Electrical Connection: M12 connector
Emerson Epro CON011/916-120 Eddy Current Signal Converter Analog Digital Module Reliability: Engineered for high reliabilityDescription This CON011 916 120 signal converter processes signals from eddy current sensors, enabling precise monitoring of radial and axial shaft displacement, position, eccentricity, and speed. It is widely used in applications such as steam turbines, gas turbines, compressors, pumps, and fans. Specifications Input Sensor Types: Compatible with PR6422, PR6423, PR6424, PR6425, and PR6426 sensors. Frequency Range: 0 to 20,000 Hz ( 3 dB). Output